HYWOS – AI assistant for plant operators
Ask the plant in plain language – HYWOS answers briefly and verified from live data and documentation. Try it right here.
Test versionFictional plant data – not connected to a real WinCC system. Answers come from prepared demo data.
HYWOS Intelligence
Test version · answers from demo data
HYWOS INTELLIGENCE
What would you like to know about the plant?
Ask about live values, alarms, interlocks or documents. Every answer names its sources.
- Live values from WinCC (simulated)
- Cited sources
- Read-only
Example questions
Electrolyser A
5 – Standby| Tag | Value | Quality |
|---|---|---|
| Operating stateElektrolyseur_A_Zustand | 5 – Standby | GOOD |
| Start permissiveElektrolyseur_A_Startfreigabe | 0 (no) | GOOD |
| Stack currentElektrolyseur_A_StackstromH 3,200 A · HH 3,400 A | 0 A | OK |
| Stack temperatureElektrolyseur_A_StacktemperaturH 80.0 °C · HH 85.0 °C | 42.6 °C | OK |
Electrolyser B
4 – Production| Tag | Value | Quality |
|---|---|---|
| Operating stateElektrolyseur_B_Zustand | 4 – Production | GOOD |
| Stack currentElektrolyseur_B_StackstromH 3,200 A · HH 3,400 A | 2,840 A | OK |
| Stack temperatureElektrolyseur_B_StacktemperaturH 80.0 °C · HH 85.0 °C | 63.8 °C | OK |
| H2 productionElektrolyseur_B_H2_Produktion | 52.4 Nm³/h | GOOD |
| O2 in H2Elektrolyseur_B_O2_in_H2H 1.00 Vol.-% · HH 2.00 Vol.-% | 0.18 Vol.-% | OK |
Compressor A
Running| Tag | Value | Quality |
|---|---|---|
| RunningVerdichter_A_Laeuft | 1 (yes) | GOOD |
| Inlet pressureVerdichter_A_Druck_EingangLL 6.0 bar(g) · L 8.0 bar(g) | 12.4 bar(g) | OK |
| Outlet pressureVerdichter_A_Druck_AustrittH 210 bar(g) · HH 220 bar(g) | 192 bar(g) | OK |
| Outlet temperatureVerdichter_A_Temperatur_AustrittH 140.0 °C · HH 155.0 °C | no valid value | BAD |
| SpeedVerdichter_A_Drehzahl | 1,480 1/min | GOOD |
H2 storage
| Tag | Value | Quality |
|---|---|---|
| Storage pressureSpeicher_DruckH 195 bar(g) · HH 200 bar(g) | 184 bar(g) | OK |
| Storage temperatureSpeicher_TemperaturH 45.0 °C · HH 55.0 °C | 18.6 °C | OK |
Utilities
| Tag | Value | Quality |
|---|---|---|
| Feed-water conductivitySpeisewasser_LeitfaehigkeitH 5.0 µS/cm · HH 10.0 µS/cm | 6.8 µS/cm | H |
| Cooling-water flowKuehlwasser_DurchflussLL 10.0 m³/h · L 12.0 m³/h | 14.6 m³/h | OK |
| H2 gas detection hallGaswarnanlage_H2_HalleH 10.0 %UEG · HH 20.0 %UEG | 0.4 %UEG | OK |
Active alarms3
- A-1042Warning·for 23 min·not acknowledged
Feed-water conductivity high (> 5.0 µS/cm)
- A-2107Fault·for 41 min·acknowledged
VD-A outlet temperature: invalid value (wire break)
- M-0315Message·for 23 min·not acknowledged
ELY-A: start permissive missing
Start permissives ELY-A
- P1Emergency-stop circuit closedmet
- P2N2 purge completemet
- P3Feed-water conductivity ≤ 5.0 µS/cmmissing
- P4Cooling-water flow ≥ 12.0 m³/hmet
- P5H2 gas detection < 10 %LELmet
- P6Storage pressure < 195 bar(g)met
What HYWOS can do
A chat assistant for plants running Siemens WinCC Unified – in German and English.
Live status
Current values, states and alarms from WinCC – with limits; signals with bad quality are flagged.Diagnosis and what-if
Explains why a unit won’t start and what the control system does in a given situation.Plant facts
Equipment, parameters, operating modes and interlocks – always with the source.Signal meaning
Turns raw values like “state 5” into plain language like “Standby”.Verified answers
Numbers, names and quotes are checked against WinCC and the source before they are shown.Read-only by design
HYWOS never writes to the plant and refuses control commands.
What HYWOS brings to operations
Less searching, fewer callbacks, safer decisions.
Faster answers
A plain-language question instead of searching folders, datasheets and screens.Fewer calls to the expert
Plant knowledge is available to every shift – also at night.Fewer wrong decisions
Verified numbers and named sources make every answer checkable.German and English
HYWOS answers in the language of the question – ideal for mixed teams.
Who it’s for
For the people at the plant
Operators
Live status, alarms and what a signal means – without the manual and without a callback.
Shift leads
Quickly understand why a unit is down and what to do next.
Service technicians
Look up interlocks, limits and the right document passage on site.
Commissioning engineers
Check signals, value texts and control logic quickly – always with the source.
A tour of HYWOS
A tour of the online demo: questions, evidence, knowledge base and live values.
Free · No obligation · approx. 30 minutes
Let’s talk about your plant.
In a free initial consultation we clarify your goals, your data situation and the feasibility – with no obligation.